Option Group 4
Feature Default Setting - I
Optional Setting
- II
Optional Setting
- III
Optional Setting
- IV
4-01
Aux 1 output 0.5sec Latch
0.5 sec Pulse +
Program
Program
4-02
Aux 2 output 0.5sec Latch
0.5 sec Pulse +
Program
Program
4-03
Aux 1 output Control By Remote Arm Disarm Panic
4-04
Aux 2 output Control By Remote Arm Disarm Start
4-05
Secure Aux Output
(1 and 2 Only)
On Off
4-06
Auxiliary Input 1 – Green CN Prewarn Trigger (-)Disarm Open Circuit
4-07
Auxiliary Input 2 – Green CN Trigger Prewarn (-)Arm Open Circuit
4-08
Extended Accessory After Ign
Shutoff (Negative Out)
Off 10 sec 30 sec
Until Door Open (1
min max)
4-11
Bypass Through RS232 Port ADS Fortin
4-12
Impact Sensor Shock Sensor DAS Sensor
4-13
Antenna Power Save Off 1 Day Later 2 Days Later 3 Days Later
4-14
Low Battery Warning Off On (at 11.3 Volts)
Option Group 3
Feature Default Setting - I
Optional Setting
- II
Optional Setting
- III
Optional Setting
- IV
3-03
Dome Light Delay Off 5 sec 45 sec Auto
3-04
Starter-Kill Relay
Anti-Grind + Starter
Kill
Anti-Grind
Anti-Grind + Passive
Starter Kill
3-05
Anti-Jacking
Starter-kill
(No Anti-Grind)
Ignition-Kill
Auto kill
(Auto-door locks Off) Inter-
national Remotes w/ AUTO
Function Only
Auto kill
3-07
Siren Duration
(Upon Alarm Trigger)
30 sec 60 sec 120 sec Chirps for 20 seconds
3-08
Horn Output (Negative Out) On Double Lock Only On Lock and Unlock
3-10
Valet
Key 5 times, or
Remote (I+III) while
Ignition is On
Key 5 times or Remote
(I+III)
Secure Valet
(Default code 3,3)
3-11
Auxiliary Settings Mode Disabled Enabled
3-15
Soft Disarm Off On
3-16
RPS RPS 2 RPS Touch