3-04 Starter-Kill – This option determines the mode of the anti-grind/starter-kill relay.
Default 1: Anti-grind + starter-kill
Option 2: Anti-grind only (no starter-kill)
Option 3: Anti-grind + passive starter-kill: starter-kill activates in 45 seconds after ignition is turned
off.
3-05 Anti-Jacking – This option requires the starter-kill relay to be wired to the ignition vs. the starter wire.
Default 1: Acts like starter-kill: removes power from the ignition, which allows the car to crank but
not start.
Option 2: Turns on anti-jacking: when the remote panics the system, power from the ignition will be
removed at the end of the 30 second siren duration, thereby disabling the vehicle.
Option 3 & 4: Only available with Canadian remotes.
IMPORTANT: When using ignition-kill on manual transmission vehicles Option 2 will need to be
utilized. Option 2 disables the anti-grind circuit while the vehicle is remote-started; if the anti-grind
circuit is active and the start-kill relay is installed in the ignition, the relay will “buzz” while remote-
started.
3-07 Siren Duration (Upon Alarm Trigger) - This option changes the time that the siren sounds during
alarm trigger. The available options are 30, 60, and 120 seconds. It will also sound chirps for 20
seconds as a fourth option.
3-08 Horn Output - This option controls the horn output during lock and unlock. The default setting will
honk the horn each time lock is pressed. The optional setting is horn honk on lock and unlock.
3-10 Valet – This option changes valet modes.
Default 1: Key on/off five times or remote valet (I + III for 0.5 seconds) with key in the on position.
Option 2: Key on/off five times or remote valet (I+III for 0.5 seconds) – key does not need to be in
the on position.
Option 3: Secure valet: RPS Valet or remote valet (I+III for 0.5 seconds) – this option prevents the
system from being put into valet via key on/off five times. To set up the RPS Valet feature, review the
“Placement and Use of Components” section.
3-11 Auxiliary settings – The Auxiliary settings adds five additional independent auxiliary outputs for a total
of seven with this option turned on. Special Option Group 1 allows for independent timing of these
outputs.
CM6300 Install Guide