3-4 Anti-Grind/Starter-Kill relay
With this option on the default setting, the starter-kill relay will act as an anti-grind circuit only. It will not disable
the starter when the system is locked/armed. On setting 2, the starter-kill relay will act as an anti-grind and starter-
kill circuit. Setting 3 is the same as 2, but a passive starter-kill is activated 45 seconds after the vehicle is turned off
or disarmed.
3-6 Factory Alarm Option
With this option turned on, the 4200DX starter only system will function as a factory style alarm by monitoring the
door trigger and sounding the horn and flashing the parking lights if the door is opened after the doors have been
locked. The system will also page the Two-Way remotes.
3-8 Horn Output
The default setting will honk the horn when tapping the lock button twice. This is only available on 1-way remotes.
Optional setting 2 will pulse the horn on lock and unlock. Optional setting 3 will pulse the horn on lock, unlock and
remote start. Optional setting 4 will pulse the horn on double lock and remote start. This will only work on 1-way
remotes.
3-10 Valet
This option changes the way you put the system into valet mode. On default setting you can either cycle the ignition
5 times with the key or turn the ignition on and tap buttons 1+3 or lock+trunk – this is a new feature in 4000 series.
Setting 2 allows you to cycle the ignition 5 times with the key or tap buttons 1+3 or lock+trunk to put the system
into valet mode. – same as CM3000 series.
Setting 3 is a secure valet: The default code is 3, 3 or any number you entered for the RPS unlock code. See page 8
of this manual or the remote user’s guide. You can change the numbers by repeating the following steps and the
first 2 numbers of RPS unlock and secure valet codes overwrite each other.
3-11 Channel Expander Mode
This option requires installation of the Channel Expander module. If you need more than the 2 supplied auxiliary
outputs, you can install the Channel Expander for 5 additional outputs. With this option turned on, POC 9 must be
set to (10) Aux 1 and becomes the data wire that communicates with the Channel Expander. Please see the Channel
Expander instruction manual for more details.
3-12 Passive Arming with Channel Expander Mode
The ability to activate/deactivate Passive Arming through the remote is lost once Channel Expander mode is
activated. If the Channel Expander is being used, set this option to Setting 2 to activate Passive Arming with
Channel Expander Mode. Leave it on the default setting to prevent Passive Arming.
4-1 Aux 1 output – This output must be set through a POC
Through the remote, this option can be programmed for the default setting of a 0.5 second pulsed output. Setting 2
changes the output to a latched setting. The latched output will stay latched until the auxiliary output is activated
again. Setting 3 changes the output of Aux 1 to a 20 second pulse. Setting 4 works in conjunction with the OP500
Option Programmer. With the OP500 you can set Aux 1 to a certain time.
4-2 Aux 2 output – This output must be set through a POC
Through the remote, this option can be programmed for the default setting of a 0.5 second pulsed output. Setting 2
changes the output to a latched setting. The latched output will stay latched until the auxiliary output is activated
again. Setting 3 changes the output of Aux 2 to a 20 second pulse. Setting 4 works in conjunction with the OP500
Option Programmer. With the OP500 you can set Aux 2 to a certain time.
4-3 Aux 1 output Control
Seitenansicht 19
1 2 ... 15 16 17 18 19 20 21 22

Kommentare zu diesen Handbüchern

Keine Kommentare