CompuSTAR CM4200DX Installationsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
7
Switch 2 sets the polarity of input for the brown/white key sense or glow plug wire on CN3, Pin 10. This switch also
is set in the Option Programming Menu. (Option 4-9) In the default position switch 2 should be down and set for
positive (+) Glow Plug input. When you change Option 4-9 to setting 2 the brown/white wire now becomes a Key
Sense input. This is used to prevent Passive arming or Setting Reservation Mode (Manual Transmission) while the key
is still in the ignition.
Switch 3 controls the output of the green/white wire Connector 1, Pin 2. The switch should be in the down position
and set for positive (+) parking light output. When you change this switch to the up position the parking light output
becomes a positive (+) trunk release wire.
________________________________________________________________________________________________
LITTLE GREEN LOOP
This jumper wire will determine the transmission setting. If the jumper wire is not cut the control module will be set for
manual transmission mode. (Note: The factory default is manual transmission. If the control module is installed in a
manual transmission vehicle and the jumper is cut ALL WARRANTY is void.) When the jumper wire is cut the
control module will be set for automatic transmission mode.
________________________________________________________________________________________________
U
PDATING THE CONTROL MODULE
The wiring diagram on the back of the control module should be marked with a “V” at the top. This shows that you
have Version 12. Version 12. If you have any other version, it will be blank or show the version number. Please check
www.compustar.com
to download the most current Control Module software. If you do not have a Version 12 or newer
we recommend you update the control module.
How to update the Control Module:
1. You need to have a USB Uploader, the part number CST-USB-ASSY (3 components – a USB cable, a USB
Module and a double head data cable.)
2. You may already have a USB Uploader for the Option Programmer OP500 or iDataLink, order the Y-adapter
data cable, part number USB-DC2. This cable is provided free of charge. The USB-DC2 is an adapter cable that
can flash either the Option Programmer OP500 or any CM4 Series Control Module.
Or, for a temporary use, you may modify a CompuStar antenna cable. See the following diagram:
3. Plug in USB connector to available USB port on computer. Do not have anything (idatalink, CM4000, OP500
etc) connected to the updater when connecting it to the computer.
4. Windows will automatically find drivers for the USB upload cable.
5. To retrieve software for updating, please email: [email protected]. Please write “request for update
software” in subject. You can also go to www.compustar.com
. Now you are ready to update your control
module
Weblink Updater