CompuSTAR CM4200DX Installationsanleitung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
15
1-7 Unlock / Disarm With Trunk Release
Unlock, Factory Disarm, and
Trunk Release
Factory Disarm, Trunk
Release Only
Trunk Release Only
V V V
1-8 Locking while in Passive Arming
Passive locking w/ Passive
Arming
No Passive Locking w/
Passive Arming
V V V
1-9 Ignition controlled door locks Off On
RPM Locks (Tach Sensing
Mode Only)
V V V
1-10
Auto Relock (If a door is not opened within this
amount of time.)
Off 30 sec 60 sec 5 min
V V V
1-11 Ignition / Accessory Out Upon Unlock Off
Ignition Pulse-same timing as
disarm pulse
Acc Pulse-same timing as
disarm pulse
Ig and Acc Pulse-same
timing as disarm pulse
V V V
OPTION GROUP 2
Setting Applicable To
Feature
Default(I) Optional(II) Optional(III) Optional(IV)
CM4000 CM4200-DX CM4300
2-1 Min. Crank Time Standard +0.2 Seconds to Crank Time
+0.6 Seconds to Crank Time
(Voltage Sensing Only)
V V
2-2 Turbo mode. Off 2 Min 1Min 4 Min
V V
2-3 Diesel timer. Wire 3~99sec (10sec Default)
V V
2-4 Trigger Start Off Single Pulse Double Pulse
V V
2-5 Cold Start with Thermistor Assembly Off On
V V
2-6
Timer Start, or, Minimum Interval Between
Cold Starts
3 Hour (4 minute runtime,
double for Diesel)
1.5 Hour (4 minute runtime,
double for Diesel)
Reservation
(Runtime 2-7)
24 Hour Repeat with Cold
Starting of 2-8
(Runtime 2-7)
V V
2-7 Remote Start Runtime 15 Min 25 Min 45 Min 3 Min
V V
2-8 Temperature of Cold Starting Off -10° C / 14° F -5° C / 23° F 0° C / 32° F
V V
2-9 Temperature of Hot Starting Off 30° C / 86° F 35° C / 95° F 40° C / 104° F
V V
2-10 Engine Sensing Tach Alternator
No Connection – Voltage
Not for Manual
Transmissions
V V
2-11
Turbo, Remote Start Runtime Extension w/ #1
for 2 seconds
No Yes
V V
OPTION GROUP 3
Setting Applicable To
Feature
Default(I) Optional(II) Optional(III) Optional(IV)
CM4000 CM4200-DX CM4300
3-1 Parking lights While Remote Started Constant Output Flashing Output Off
V V
3-2 Dome Light output Off Factory Rearm 45 sec Factory Rearm + 45 Sec
V V V
3-3 Dome Light Delay Off 5 sec 45 sec Auto
V V V
3-4 Starter-Kill relay. Anti-Grind Anti-Grind + Starter Kill
Anti-Grind + Passive
Starter Kill
V V
3-5 Anti-Jacking Starter-Kill
Ignition-Kill
(no Anti-Grind)
Auto kill
(Auto-door locks Off)
Canadian Remotes w/ AUTO
Function Only
Auto kill
(Auto-door locks On)
Canadian Remotes w/ AUTO
Function Only
V V
3-6 Factory Alarm Option Off On (4200DX Only)
V
3-7 Siren Duration (Upon Alarm Trigger) 30 sec 60 sec 120 Sec Chirps for 20 seconds
V V
3-8 Horn Output On Double Lock Only On Lock and Unlock On Lock, Unlock, and Start On Double Lock and Start
V
3-9
Horn Output (4000/4300) When Alarm Is
Triggered
Pulsed Output
(Horn)
Constant Output (Secondary
Siren)
V V
3-10 Valet
Key 5 times, or Remote
(I+III) while Ignition is On
Key 5 times or Remote
(I+III)
Secure Valet(Default code
3,3)
V V V
3-11 Channel Expander Mode Disabled Enabled
V V V
3-12
Passive Arming with Channel Expander
enabled
No Passive Arming Passive Arming
V V V
OPTION GROUP 4
Setting Applicable To
Feature
Default(I) Optional(II) Optional(III) Optional(IV)
CM4000 CM4200-DX CM4300
4-1 Aux 1 output 0.5sec Latch 20 sec Program
V V V
4-2 Aux 2 output 0.5sec Latch 60 sec Program
V V V
4-3 Aux 1 output Control By Remote Arm Disarm Panic
V V V
4-4 Aux 2 output Control By Remote Arm Disarm Panic
V V V
4-5 Secure Aux Output (1 and 2 Only) On Off
V V V
4-6 Auxiliary Input 1 Prewarn Trigger (-)Disarm
V V
4-7 Auxiliary Input 2 Trigger Prewarn (-)Arm
V V
4-8 Extended Accessory After Ign Shutoff Off 10 sec 30 sec Until Door Open (1 min max)
V V V
4-9 Key Sense or Glow Plug input Glow Plug Input Key Sense Input
V V
4-10 Trigger Start or Closed Loop System Input Trigger Start input Closed Loop System Input
V V V
SPECIAL OPTION GROUP #1
Applicable To
Feature Setting Value [seconds]
CM4000 CM4200-DX CM4300
1 Diesel timer 3 ~ 99
V V
2 AUX1 output time 1 ~ 100
V V V
3 AUX2 output time 1 ~ 100
V V V
4 AUX3 output time 1 ~ 100
V V V
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 22

Kommentare zu diesen Handbüchern

Keine Kommentare